| Load cell repair and
calibration SERVICE
PCM have their own in house design service
to manufacture load cells to your requirements and dimensions. The
service has been set up to gain maximum efficiency to enable to
provide the quickest service without compromising on quality.
|
MACHINES
- ±100kN
Hand Press.
- -300kN to +400kN Amsler Machine.
- 0-2800kN Losenhausen Compression
Machine.
- Selection of Dead Weights.
- All independently calibrated by UKAS
Traceable Contractor.
|
PCM offers a full repair and calibration service
for damaged, suspect or working load cells. We are able to work
on most load cell makes and models from small to very large capacities.
This service could eliminate the need to purchase
new replacement load cells and so making considerable savings.
Each load cell is fully tested to diagnose the problem and a list
of the faults will be presented along with the recommendations.
The load cell is tested and calibrated to ensure optimum performance.
We have in house ability to test various designs
of load cells from 30Te in tension to 280Te in compression from
our selection of four test rigs and dead weights.
Each re-calibration undergoes a five point
linearity run and three times repeatability over the full specified
loading range. Below is an example of a supplied certificate:
Customer Options
- To alter the calibration format that suits
the customers application, ie:- increased number of points or
vary the scatter of points in a particular area of the calibration
curve.
- To supply copies of the test machine certificates
to maximise the traceability.
To complete a calibration we would require
the following information:
- Type of calibration: Tensile, compression,
torsion.
- Number of linearity points.
- Desire units of calibration.
- If an indicator is connected to the load
cell, to have automatic calibration adjustment.
- Desired accuracy of calibration.

|